IMG1605245
IMG1605245
Moisture in corner.
IMG1605246
IMG1605246
Moisture in corners.
IMG1605248
IMG1605248
Corners have moisture.
IMG1605279
IMG1605279
Troughs are clean.
IMG1605282
IMG1605282
Open V-shaped valley.
IMG1605284
IMG1605284
Shingles are in good condition.
IMG1605285
IMG1605285
Low vent.
IMG1605286
IMG1605286
No soffit intake.
IMG1605287
IMG1605287
Another low vent.
IMG1605290
IMG1605290
Four low vents total.
IMG1605291
IMG1605291
Gable vent.
IMG1605295
IMG1605295
Chimney flashing looks good.
IMG1605297
IMG1605297
Bathroom fan pipe not insulated.
IMG1605298
IMG1605298
Nails caulked on the vents and flashings.
IMG1605304
IMG1605304
Gable vent combined with roof vents.
IMG1605305
IMG1605305
No soffits on the house.
IMG1605306
IMG1605306
Pot lights not properly shielded and no vapour barrier installed in the attic.
IMG1605313
IMG1605313
Downpipe at the back of the house not secured to the wall.
IMG1605328
IMG1605328
Frost present on nails and mold starting on roof deck boards.
IMG1605329
IMG1605329
Attic hatch in bedroom.
IMG2030800
IMG2030800
Repair: installed attic baffles.
IMG2030806
IMG2030806
Closed off gable vent.
IMG2032341
IMG2032341
Plugged vent with easy plug.
IMG2032345
IMG2032345
Removed two rows of shingles.
IMG2032901
IMG2032901
Edge vent installed.
IMG2032902
IMG2032902
Ice and water shield installed over edge vent.
IMG2032913
IMG2032913
Low vents closed with engineered roof patches.
IMG2032918
IMG2032918
IMG2033009
IMG2033009
IMG2034136
IMG2034136
Shingles installed over edge vent to complete.
IMG2034142
IMG2034142
Additional vent installed for exhaust.
IMG2034222
IMG2034222
Re-secured downpipe.

The Challenge

The Client contacted Mr. Roof Repair because of condensation issues. She noticed wet marks on four corners of the house on the ceilings.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team performed a full assessment of the roof and attic. They found that the ventilation system is suffering as a result of undervented soffits and inadequate air intake. The exhaust vents were installed too low from the ridge of the roof and the insulation is poor quality. There is no vapour barrier, there are uninsulated and unsealed pot lights and the bathroom fan pipe is not insulated.

A quote was provided to correct these issues, which the Client accepted and work commenced.