68 - IMG5470136
68 - IMG5470136
There are water marks on the ceiling.
69 - IMG5470153
69 - IMG5470153
Stains on the ceiling.
70 - IMG5470162
70 - IMG5470162
Stains near the bathroom wall.
71 - IMG5470174
71 - IMG5470174
Stains on the interior wall.
72 - IMG5470195
72 - IMG5470195
There is a stain on the ceiling above the bed, near the window.
78 - IMG5471212
78 - IMG5471212
There are four exhaust vents installed at the rear. The lower vents are short-circuiting the ventilation system as they are acting as intake.
IMG5547420
IMG5547420
The lower exhaust vents were removed and engineered wood patches were used to close the holes.
IMG5547590
IMG5547590
New shingles were installed where the exhaust vents were removed.

The Challenge

The Client contacted Mr. Roof Repair because they have some moisture coming in through the bathroom vent.

The Solution

Mr. Roof Repairs Roofing Specialist (RS) Team confirmed that the moisture is a result of condensation within the attic space. They noted that while there is sufficient air intake from the soffits, some of the exhaust vents were installed incorrectly.

There are four exhaust vents on the rear of the home that had been installed in a box pattern. This is a problem because the upper vents are pulling air from the lower vents instead of the soffits, which was completely disrupting the flow of air through the system.

It was recommended that the two lower box vents be removed from the roof, in order to correct the ventilation system. A quote was provided to this effect. The quote was accepted and work commenced.