135 - IMG_F011DDF6-9725-C5E8-7F0C-AEBAEDE61EDD
135 - IMG_F011DDF6-9725-C5E8-7F0C-AEBAEDE61EDD
Area located for bathroom vent.
136 - IMG_F4300913-F949-B630-9DB1-09DD33B5CD55
136 - IMG_F4300913-F949-B630-9DB1-09DD33B5CD55
Collar installed.
137 - IMG_CD7B3E42-1E4D-E789-C25B-22099A9A53D7
137 - IMG_CD7B3E42-1E4D-E789-C25B-22099A9A53D7
Membrane on the back dormer is cracked and may be leaking.
138 - IMG_13A544D1-0FAB-6FFB-0F79-8B12B422D5A8
138 - IMG_13A544D1-0FAB-6FFB-0F79-8B12B422D5A8
Bathroom flapper vent installed.
139 - IMG_90AF82E7-D2DE-9C9D-1D48-3BF3243DB6D4
139 - IMG_90AF82E7-D2DE-9C9D-1D48-3BF3243DB6D4
Cedar walls need to be replaced. They are cracked and old and are leaking into the bedroom.
140 - IMG_F73B2F4D-8C1C-E7CC-8F5C-167D585658DB
140 - IMG_F73B2F4D-8C1C-E7CC-8F5C-167D585658DB
Nails driven through the roof in the flat located on the back.
141 - IMG_7907DDC6-13C4-171A-FC5D-70ADF2EA1014
141 - IMG_7907DDC6-13C4-171A-FC5D-70ADF2EA1014
Shingles still in good health here.
142 - IMG_701AB04C-000D-D115-0BF8-8B44A41A8AAE
142 - IMG_701AB04C-000D-D115-0BF8-8B44A41A8AAE
Slant back venting. Has sufficient ventilation for home.
143 - IMG_AD1425D7-27B9-66A6-F9F9-E2F7C6499FF1
143 - IMG_AD1425D7-27B9-66A6-F9F9-E2F7C6499FF1
Shingles installed low at the transition. Membrane should come up 3 feet from the transition to avoid nailing and leaks.
144 - IMG_E78D00BB-646B-B9BF-765E-1F68DF69CE8A
144 - IMG_E78D00BB-646B-B9BF-765E-1F68DF69CE8A
Cedar is cracked and open.
145 - IMG_B2353F53-3523-E8EB-7CDB-4CECBC3C0C2E
145 - IMG_B2353F53-3523-E8EB-7CDB-4CECBC3C0C2E
Pic of the cedar.
146 - IMG_C701B99A-40D6-1ED6-1B2A-F983E73593A6
146 - IMG_C701B99A-40D6-1ED6-1B2A-F983E73593A6
Eaves are in good shape. There is no standing water and they are clean.
147 - IMG_A0AE4BAD-D45A-8133-5488-E38EB25F2E71
147 - IMG_A0AE4BAD-D45A-8133-5488-E38EB25F2E71
Membrane is cracked.
148 - IMG_9F1F1DAF-F4AD-B8D3-D12B-61D3D045286B
148 - IMG_9F1F1DAF-F4AD-B8D3-D12B-61D3D045286B
Chimney flashing sealed.
149 - IMG_8D0CE5D2-79E5-F2D9-5535-3FCB90ADDE56
149 - IMG_8D0CE5D2-79E5-F2D9-5535-3FCB90ADDE56
Four dormers in total to be dressed in shingles or siding.
150 - IMG_2837AC8B-F8E1-E45C-5040-67ECEACCA845
150 - IMG_2837AC8B-F8E1-E45C-5040-67ECEACCA845
Hose clamped and connected.
151 - IMG_C19B9F9A-6555-24B5-37D6-8C52F8A391E2
151 - IMG_C19B9F9A-6555-24B5-37D6-8C52F8A391E2
Connected.

The Challenge

The Client approached Mr. Roof Repair requesting the installation of a bathroom vent and hose.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team installed and sealed a proper bathroom vent complete with connecting insulated hose. Then they performed a full roof assessment where they found that the cedar shakes are in poor condition and need to be replaced as they are allowing water to leak into the home. The flat roof is also in disrepair as it has cracked and nails have driven directly through the membrane.