Plumbing stack sealed well.
IMG1768280
IMG1768280
Seams are sealed well on this flat roof.
IMG1768283
IMG1768283
Skylight looks good.
IMG1768284
IMG1768284
Two panel vented soffits at the front.
IMG1768285
IMG1768285
Shingles on the back slope are in good shape.
IMG1768286
IMG1768286
Soffits blocked by wood at the back.
IMG1768287
IMG1768287
Valley looks good.
IMG1768292
IMG1768292
Exposed nails on the shingles.
IMG1768295
IMG1768295
Shingles on the front slope are in decent shape.
IMG1768296
IMG1768296
Eavestrough.
IMG1768299
IMG1768299
Missing a piece of fascia.
IMG1768300
IMG1768300
Wall is not properly installed. There is no step flashing.
IMG1768304
IMG1768304
Two panel venting soffits on the lower roof at the front.
IMG1768307
IMG1768307
Wall flashing used as counter flashing.
IMG1768314
IMG1768314
Not sealed properly at the top of the flashing.
IMG1768320
IMG1768320
Back flat roof consists of multiple layers.
IMG1768321
IMG1768321
Downpipe is draining onto the lower roof at the front.
IMG1768324
IMG1768324
Shingles on the garage are in bad shape.
IMG1768327
IMG1768327
Eaves at the back are in bad shape.
IMG1768329
IMG1768329
Eaves on the upper back flat are not sloping properly.

The Challenge

The Client contacted Mr. Roof Repair for a full roof assessment.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team performed the assessment and identified the following issues:

  • There is missing fascia, the eavestrough are not draining properly and the downpipes are located in the wrong place
  • The roof is undervented and the soffits are blocked
  • The chimney is in disrepair with improperly sealed corners and seams and the wall flashing is not properly installed