394 - IMG2509612
394 - IMG2509612
Soffit, fascia and eavestrough are in decent shape although the soffit is non-venting.
395 - IMG2509621
395 - IMG2509621
Flat roof is in good shape.
396 - IMG2509627
396 - IMG2509627
Shingles are in good shape.
397 - IMG_FFD8B8C3-0A6E-46E3-B80C-C84FD2D6572D
397 - IMG_FFD8B8C3-0A6E-46E3-B80C-C84FD2D6572D
Seams are sealed well on the flat roof.
398 - IMG_CDE77D88-BFAB-4666-322C-46F144000126
398 - IMG_CDE77D88-BFAB-4666-322C-46F144000126
Flashing is rusty and old.
399 - IMG2509647
399 - IMG2509647
Deterioration, balding, curling and cracking on the mansard wall.
400 - IMG_C5279AE9-40A1-8C5F-1641-0DB372FD0C93
400 - IMG_C5279AE9-40A1-8C5F-1641-0DB372FD0C93
Hole in caulking / not sealed properly.
401 - IMG_5E22D4BE-314E-41F4-89AB-39050DD2D411
401 - IMG_5E22D4BE-314E-41F4-89AB-39050DD2D411
Shingles are in good condition.
402 - IMG_2FE92FB3-7ECC-F658-D5C3-6E2D0DFB4F17
402 - IMG_2FE92FB3-7ECC-F658-D5C3-6E2D0DFB4F17
Cross venting.
403 - IMG2509666
403 - IMG2509666
Flat membrane not finished properly. Should be running up the wall and under the shingles.
404 - IMG2509675
404 - IMG2509675
Membrane should run higher on the wall and flashing installed over top.
405 - IMG2509747
405 - IMG2509747
Shingles on the neighbour's side that is attached are in bad shape and have multiple areas where water can get in and behind the homeowner's flashing.
406 - IMG2509749
406 - IMG2509749
Neighbour's wall.
407 - IMG2509752
407 - IMG2509752
Neighbour's wall.
408 - IMG2509777
408 - IMG2509777
Membrane should be running up the wall.

The Challenge

The Client contacted Mr. Roof Repair to get an in-depth look at their roof to get an idea on the health and life of their entire roof. Also, the Client has a leak in the back addition that they would like investigated.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team investigated and found that the shingles on the mansard wall of the back dormer are in bad shape and need to be replaced in the immediate future. The flat membrane that the previous roofers have installed is improper. They have ended it short in all the problem areas where it should be run up the wall and under the shingles. The neighbour’s wall also has shingles that are in very bad shape and there are many areas where water is getting in and able to leave behind the Client’s flashing. This is the main cause of the leak in the back room.

A quote was provided to correct the issues found.