IMG1925594
IMG1925594
The back slope has extreme curling of the shingles.
IMG1925602
IMG1925602
Close up of the curling.
IMG1925605
IMG1925605
It appears that the skylight was replaced more recently than the rest of the roof.
IMG1925608
IMG1925608
Proper bathroom vent.
IMG1925611
IMG1925611
Plumbing stack is in good shape and sealed well.
IMG1925616
IMG1925616
All vent fasteners are sealed.
IMG1925625
IMG1925625
Chimney flashing is in good shape and sealed well.
IMG1925634
IMG1925634
Chimney is starting to fall apart.
IMG1925643
IMG1925643
Four box vents.
IMG1925652
IMG1925652
Front slope is in decent shape.
IMG1925654
IMG1925654
Front slope is in decent shape.
IMG1925704
IMG1925704
Big hole in the flat.
IMG1925708
IMG1925708
Exposed hole at the drip edge.
IMG1925711
IMG1925711
Flat roof is missing flashing.
IMG1925714
IMG1925714
Open hole against the wall.
IMG1925720
IMG1925720
Large hole against the wall, missing wall flashings.
IMG1925724
IMG1925724
Another large hole where the flat roof meets the shingles.
IMG1925726
IMG1925726
Hole in the flat roof.
IMG1925732
IMG1925732
Flat roof has lost the seal at the drip edge.
IMG1925741
IMG1925741
Flat roof has lost the seal at the seams.

The Challenge

The Client contacted Mr. Roof Repair for a full roof assessment. They were experiencing a leak and needed to know where it was coming from.

The Solution

The Roofing Specialist (RS) Team determined there were four main areas of the roofing system that had issues. The ventilation system was suffering as a result of inadequate air intake and the exhaust vents were placed too low from the ridge line to effectively draw the hot air out of the attic space. The shingles on the back slope were in poor condition and needed to be replaced as they were curling, cracking and balding (granular loss). There was a big hole in the flat roof and another large hole where the flat roof meets the shingles. the flat roof membrane had also lost its seal at the drip edge and at the seams. Finally, the flashing on the roof was inadequate. There were areas that were missing the flashing and other areas where the flashing had holes in them.