42 - IMG2563970
42 - IMG2563970
Leak at rear left room of home.
43 - IMG2563987
43 - IMG2563987
Cracking in the upper rear right bedroom.
44 - IMG2564128
44 - IMG2564128
Some staining on the rafters of the garage roof.
45 - IMG2564215
45 - IMG2564215
46 - IMG2564227
46 - IMG2564227
Low vents used for intake. Improper.
47 - IMG2564233
47 - IMG2564233
Fascia and eavestrough missing on the front of the house.
48 - IMG2564245
48 - IMG2564245
Power vent.
49 - IMG2564253
49 - IMG2564253
Plumbers flashing not layered in.
50 - IMG2564286
50 - IMG2564286
Step flashings not installed properly on chimney.
51 - IMG2564292
51 - IMG2564292
Back pan draining under the shingles.
52 - IMG2564309
52 - IMG2564309
Many shingles missing and the remaining are balding, degranulated and falling apart on the south side.
53 - IMG2564376
53 - IMG2564376
Wall flashing has separated from the wall.
54 - IMG2564395
54 - IMG2564395
Ponding water on the flat roof.
55 - IMG2564418
55 - IMG2564418
Seams are starting to separate on the flat roof.

The Challenge

The Client contacted Mr. Roof Repair because they have a leak and want to determine the source of the leak as well as receive a full assessment of their roofing system.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team discovered that on the south side of the house, the shingles are completely worn out and the other shingles are getting close to needing replacement. There is also water pooling on the flat roof which is putting a strain on the seams which are already starting to separate. The RS Team also found that the flashings were not layered in properly and the chimney flashing was corroded and needed to be replaced. There is missing fascia and eavestrough on the front of the house and the rest of the trough is leaking at the corners and seams. The ventilation system is also incorrect: there are low exhaust vents being used for air intake.

A quote was provided to replace the roof.