IMG1679718
IMG1679718
Shingles under required slope.
IMG1679720
IMG1679720
Downpipe draining onto the lower roof and the roof is undervented.
IMG1679730
IMG1679730
Cross vented.
IMG1679732
IMG1679732
Front corners of flashing have no extension.
IMG1679738
IMG1679738
Nails through valley.
IMG1679747
IMG1679747
Nails are too close to valley and points not dubbed.
IMG1679752
IMG1679752
Front slope degranulation.
IMG1679754
IMG1679754
Open valley.
IMG1679758
IMG1679758
Over exposed and the shingles are extended.

The Challenge

The Client contacted Mr. Roof Repair because water was leaking from the chimney on the left side of the roof. The roof above the garage is a new addition done three years prior, so the Client believed the issue was coming from the connection point between the addition and the original roof.

The Solution

Upon inspection, Mr. Roof Repair’s Roofing Specialist (RS) Team determined that the shingles were in poor condition and needed to be replaced. They were installed under the required slope and are over exposed, cracking and balding. A quote to redo the roof was provided.