190 - IMG_F395F153-D63A-F3B5-8BDC-F13F352A0C44
190 - IMG_F395F153-D63A-F3B5-8BDC-F13F352A0C44
No intake. Soffits closed.
191 - IMG_7A8CA0F3-0A31-A583-8158-08269256CAED
191 - IMG_7A8CA0F3-0A31-A583-8158-08269256CAED
Open rafter and no soffit intake found.
193 - IMG_289B33BA-C8BF-797A-F522-B6B8D603C71F
193 - IMG_289B33BA-C8BF-797A-F522-B6B8D603C71F
Shingles are cracked and need to be replaced.
194 - IMG_4B235C82-9E51-7BFE-2A10-67BAFE72C049
194 - IMG_4B235C82-9E51-7BFE-2A10-67BAFE72C049
195 - IMG_D85D9C76-D7A9-1781-C299-CFAB890DFAC7
195 - IMG_D85D9C76-D7A9-1781-C299-CFAB890DFAC7
Wall vent needed for the lower half of the roof. Space needs to be treated separately from the main roof above the transition.
196 - IMG_8A62A691-512C-C86D-2E93-02158981B3D9
196 - IMG_8A62A691-512C-C86D-2E93-02158981B3D9
No ice and water shield was installed. Felt paper was used on a 3 foot section. This was an incorrect use of the material.
197 - IMG_8464CF57-105B-8280-123F-5C250410FAFA
197 - IMG_8464CF57-105B-8280-123F-5C250410FAFA
Eavestroughs are in good shape. No issues.
198 - IMG_F101251C-5E75-FE8F-C80C-645EFF6C4C12
198 - IMG_F101251C-5E75-FE8F-C80C-645EFF6C4C12
Shingles cracked.
199 - IMG_1F6B762A-CE71-7E41-3457-7EAFD9CD4993
199 - IMG_1F6B762A-CE71-7E41-3457-7EAFD9CD4993
Flashings still sealed on the chimney.
200 - IMG_E47B60C6-7B8D-28DD-E9BF-0B904B25897C
200 - IMG_E47B60C6-7B8D-28DD-E9BF-0B904B25897C
Shingles cracked at the valley.
201 - IMG_22066916-691A-4D7D-CFC5-4E0C052F9B7F
201 - IMG_22066916-691A-4D7D-CFC5-4E0C052F9B7F
Chimney flashing is ok.
202 - IMG_226FB4F9-6165-B44B-4AE1-F4E44CB6E212
202 - IMG_226FB4F9-6165-B44B-4AE1-F4E44CB6E212
Venting is inadequate. A ridge vent system is needed.
203 - IMG_8A95C1F7-3516-579D-1B2E-DF9E38A62E1B
203 - IMG_8A95C1F7-3516-579D-1B2E-DF9E38A62E1B
Not enough venting and there are different types of louvers.
204 - IMG_C357E5EE-0159-8635-50AD-820CF2F615EE
204 - IMG_C357E5EE-0159-8635-50AD-820CF2F615EE
205 - IMG_69E5784C-ED4B-4BE3-F092-0E0A42175195
205 - IMG_69E5784C-ED4B-4BE3-F092-0E0A42175195
206 - IMG_F56D977E-8C78-5B8C-E77F-4C57240DE5AE
206 - IMG_F56D977E-8C78-5B8C-E77F-4C57240DE5AE
280 - IMG_125D532B-5CFD-1F52-76C5-96BFE37AF6DD
280 - IMG_125D532B-5CFD-1F52-76C5-96BFE37AF6DD
Shingles cracked and need to be replaced.

The Challenge

The Client contacted Mr. Roof Repair because they had their roof done 12-14 years ago but have had issues since the beginning. The roof is looking quite worn in areas. They also noticed an area in a closet that is showing mold, which is located at the right side of the home at the second floor slope. They requested a detailed assessment of the roof.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team determined that the shingles are in poor condition and need to be replaced. The ridge and hip capping is worn through to the roof deck, has exposed fasteners and is overexposed. The field shingles are curling, cracking and balding (granular loss), have algae growth and there are nails popping out of the roof deck. They also found that the ventilation system is suffering as a result of undervented soffits and inadequate air intake as well as a mixture of exhaust vents that are rendering the ventilation system inefficient.