IMG1869030
IMG1869030
Soffit, fascia, eaves and downpipe appear weathered and the eaves are very dirty.
IMG1869045
IMG1869045
Hips are deteriorating on the front of the house.
IMG1869047
IMG1869047
Back slope has deteriorated.
IMG1869049
IMG1869049
The back upper slope is in decent shape.
IMG1869050
IMG1869050
The back lowest slope is in bad shape and is heavily deteriorated.
IMG1869055
IMG1869055
Missing wall flashing on the back lowest slope.
IMG1869061
IMG1869061
Plumbing stack is in good shape and sealed well.
IMG1869062
IMG1869062
Old style ridge vent.
IMG1869065
IMG1869065
Ridge vent lifted.
IMG1869070
IMG1869070
Deterioration on the back slope.
IMG1869076
IMG1869076
Chimney flashing is in good shape and sealed well.
IMG1869083
IMG1869083
Front valleys are beginning to bald.
IMG1869091
IMG1869091
Four valleys on the house.
IMG1869098
IMG1869098
No step flashings installed on the catwalk.
IMG1869101
IMG1869101
Balding in the valleys.
IMG1869110
IMG1869110
Trough draining onto lower roof.
IMG1869118
IMG1869118
Troughs draining onto lower roof.
IMG1869123
IMG1869123
Missing a downpipe.
IMG1869127
IMG1869127
Back of the house.
IMG1869129
IMG1869129
Back lower roof is heavily deteriorated.
IMG1869131
IMG1869131
Missing counter flashing.

The Challenge

The Client contacted Mr. Roof Repair because their roof is 25 years old and they wanted to get a quote for a reroof.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team performed a full assessment of the roof and found the following issues:

  • The eavestrough are pulling away from the fascia in several spots and there is a downpipe draining directly onto the roof below causing the deterioration of the shingles in the surrounding area
  • The ridge vent has no external baffle and water is blowing up underneath it
  • The shingles are in poor condition and need to be replaced as they are curling, cracking and balding (granular loss)
  • The valley is balding and there are missing flashings