1 - IMG_0D774927-8453-242E-9E98-25475620A9D7
1 - IMG_0D774927-8453-242E-9E98-25475620A9D7
Leak marks around the bathroom fan.
3 - IMG_95D753B1-1023-86E8-7D92-E7A1394A51AC
3 - IMG_95D753B1-1023-86E8-7D92-E7A1394A51AC
The drip edge is raised, which is causing water to pool and possibly back up at the edge of the roof.
5 - IMG_6D5E7D2C-F3C9-70F7-E6B5-A2D914090407
5 - IMG_6D5E7D2C-F3C9-70F7-E6B5-A2D914090407
The same issue is occurring at the opposite side of the roof as well.
1
1
There is a small overlap on the drip edge.
2
2
This drip edge needs to be replaced.
3
3
The membrane was cut out.
4
4
The membrane was dried.
5
5
Roof cement was applied to the base sheet.
6
6
New drip edge was installed.
8
8
New membrane was installed along the edges on both sides of the home.
9
9
New metal drip edge installed.

The Challenge

The Client approached Mr. Roof Repair with concerns about a leak that was occurring on their flat roof. The same leak had also happened in the same area, the previous year.

The Solution

Mr. Roof Repairs Roofing Specialist (RS) Team determined that water is leaking into the home, where the drip edge meets the flat roof membrane.

It was recommended that the drip edge be replaced, and a new membrane be applied along the perimeter of the flat roof on both sides of the home, in order to prevent further issues from occurring.

A quote was provided to this effect. The quote was accepted and work commenced.

Related Projects