409 - IMG_25FD50C8-8A93-DF9F-807A-5A783268096C
409 - IMG_25FD50C8-8A93-DF9F-807A-5A783268096C
Fascia missing along the gable.
410 - IMG_4257A7CD-DDE5-37A6-B158-7AC53197BDFE
410 - IMG_4257A7CD-DDE5-37A6-B158-7AC53197BDFE
New fascia to be installed.
411 - IMG_2B5DC287-38CA-7C26-5C8D-EDF8FB1A055B
411 - IMG_2B5DC287-38CA-7C26-5C8D-EDF8FB1A055B
New fascia installed and secured.
412 - IMG_F79C7DF5-F169-79EC-0241-67CCAC97029D
412 - IMG_F79C7DF5-F169-79EC-0241-67CCAC97029D
Venting is insufficient. Ridge venting is needed.
413 - IMG_8BC55D74-924A-8D4C-3E02-1FCC62F35DCA
413 - IMG_8BC55D74-924A-8D4C-3E02-1FCC62F35DCA
Shingles were nailed high.
414 - IMG_4C7A6276-2393-B614-A3C3-71157D490E56
414 - IMG_4C7A6276-2393-B614-A3C3-71157D490E56
In some areas the shingles were nailed more than once and in other areas they were not nailed at all.
415 - IMG_979FC704-5583-36B3-6531-7ED577C318CF
415 - IMG_979FC704-5583-36B3-6531-7ED577C318CF
Valleys are ok.
416 - IMG_4EB598C2-358D-75BA-6694-CBA565A272B8
416 - IMG_4EB598C2-358D-75BA-6694-CBA565A272B8
Shingles are nine years old but in fair shape overall.
417 - IMG_FF06E464-55B7-1283-F7DA-6F7D7E847A8C
417 - IMG_FF06E464-55B7-1283-F7DA-6F7D7E847A8C
Nails driven through the shingles causing leaks.
418 - IMG_7EB20A54-3C59-3A9F-06ED-408F7A93C414
418 - IMG_7EB20A54-3C59-3A9F-06ED-408F7A93C414
Before shot of the cap on the siding.
419 - IMG_F4024351-FD12-FF67-D48D-9BA5BA4213A4
419 - IMG_F4024351-FD12-FF67-D48D-9BA5BA4213A4
Repair to siding.
420 - IMG_1F4A50C6-9CC3-881C-A8FB-4574D3572AD8
420 - IMG_1F4A50C6-9CC3-881C-A8FB-4574D3572AD8
Flashing sealed.
1-IMG_685472BF-E26D-3304-41B3-FEDA2079F48D
1-IMG_685472BF-E26D-3304-41B3-FEDA2079F48D
Attached insulated hose to fan.
4-IMG_D059E351-3688-1CC3-B8D7-D75CDF8A3A62
4-IMG_D059E351-3688-1CC3-B8D7-D75CDF8A3A62
Attached hose to collar on roof.
3-IMG_2C903F0E-BC8A-E5EC-3D68-61A79A9A282F
3-IMG_2C903F0E-BC8A-E5EC-3D68-61A79A9A282F
Removing shingles and replacing.
2-IMG_0F10279C-8B68-43A1-717F-6D16A75BAA2C
2-IMG_0F10279C-8B68-43A1-717F-6D16A75BAA2C
Bathroom vent installed.

The Challenge

The Client contacted Mr. Roof Repair because they had some fascia metal that had blown off their roof.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team installed and sealed the new fascia metal and re-installed the siding that had popped up, back into place. Then they performed a full roof assessment where they identified a bathroom exhaust hose that was not connected properly to the vent. This causes the vents to exhaust into the attic area which can lead to moisture build-up and mold growth. A quote was provided to attach the hose properly and work commenced.