Exposed wood.
254 - IMG_CE0C8DD2-F7EB-9C78-CA1D-4754EA99C04C
254 - IMG_CE0C8DD2-F7EB-9C78-CA1D-4754EA99C04C
Animal damage to the shingles and open fascia exposed allowing water to enter under the flat roof.
255 - IMG_B8B7B171-A063-9F89-EE58-406FCF3EA19A
255 - IMG_B8B7B171-A063-9F89-EE58-406FCF3EA19A
Edges of the flat roof starting to open and allowing water to leak in.
256 - IMG_7474828E-3D29-4DC0-C6E2-1C1A82F290EB
256 - IMG_7474828E-3D29-4DC0-C6E2-1C1A82F290EB
Membrane open.
257 - IMG_0D18DBD2-CAE2-E183-9D8A-1170EF272067
257 - IMG_0D18DBD2-CAE2-E183-9D8A-1170EF272067
Flat roof is starting to blister and the seams are opening.
258 - IMG_3BD4A32B-11B3-4CDC-7ED1-7C7B8704D9D0
258 - IMG_3BD4A32B-11B3-4CDC-7ED1-7C7B8704D9D0
No issues at the chimney.
259 - IMG_4A6D7E5C-37D9-95E0-200F-7EA7F3F6C791
259 - IMG_4A6D7E5C-37D9-95E0-200F-7EA7F3F6C791
Shingles on the main roof are still in good shape.
260 - IMG_AEE7E800-F5A2-DECC-9CA7-4BEC7F154A6C
260 - IMG_AEE7E800-F5A2-DECC-9CA7-4BEC7F154A6C
Top of the chimney needs a protective screen.
261 - IMG_93243AAD-75CA-D1B4-233F-5D0683773EF9
261 - IMG_93243AAD-75CA-D1B4-233F-5D0683773EF9
Roof is badly cracked.
262 - IMG_8CFDA571-0DA7-2444-03C5-2F409E01957D
262 - IMG_8CFDA571-0DA7-2444-03C5-2F409E01957D
Full view of the flat roof. A coating is recommended.
263 - IMG_32E87711-AA00-B866-0FF5-C1E3F5177AB7
263 - IMG_32E87711-AA00-B866-0FF5-C1E3F5177AB7
Roof boards are popped and cracked. Small area needs to be replaced.
264 - IMG_13A60FA5-BFE5-CB48-1132-D0B23CB5C1AC
264 - IMG_13A60FA5-BFE5-CB48-1132-D0B23CB5C1AC
Shingles are coming off.
265 - IMG_7621A5A7-A602-76E1-A7AC-6A532323FFCA
265 - IMG_7621A5A7-A602-76E1-A7AC-6A532323FFCA
Shingles need to be replaced by the dormer at the back of the home.
266 - IMG_FA83858A-BBE6-465B-209D-B627C5A5589D
266 - IMG_FA83858A-BBE6-465B-209D-B627C5A5589D
Temp repair done and area close with metal.
267 - IMG_3401D282-D889-C8F2-3AB2-1FAB72C992FA
267 - IMG_3401D282-D889-C8F2-3AB2-1FAB72C992FA
Pigeon spikes to be installed on the windows.
268 - IMG_DA147B00-CBFD-EE22-2CFD-02E1B5C3A284
268 - IMG_DA147B00-CBFD-EE22-2CFD-02E1B5C3A284
Temps to the seams.
269 - IMG_4DEC3DF7-E01A-BC5A-188E-741CB9DEA4E3
269 - IMG_4DEC3DF7-E01A-BC5A-188E-741CB9DEA4E3
Flat roof with temp to the seams.

The Challenge

The Client approached Mr. Roof Repair with concerns about a leak at the rear of the home.

The Solution

Mr. Roof Repair’s Roofing Specialist (RS) Team determined the leak was the result of animal damage to the roof deck and shingles. The RS Team temporarily closed the area off with metal but it was determined that a more permanent solution was required. They also sealed the edge of the flat roof with waterproof roof cement as they had started to open and were allowing water to leak in.